Solar repair guide
Solar generation meter not working? What to check and what to do
If your solar generation meter is blank, stuck or has stopped counting, the panels may be fine and only the meter may have failed. Either way, act quickly, because a feed-in tariff (FIT) is paid on the readings from that meter. This guide shows you how to tell a meter fault from a system fault, and what to do next.
Mon–Fri 9:00am–5:00pm · Clear written quote before any work starts
Talk to us about solar, batteries or repairs.
Call 0800 156 0191, Monday to Friday, 9:00am–5:00pm, or send us a message through our contact page.
MCS certified
NAPIT registered
TrustMark approved
Fully insured
England, Wales & Scotland
Check first
Is it the meter or the system?
It covers a meter that has stopped working. If you only need to know how to read a working meter, see our FIT meter readings guide.
The generation meter only counts the electricity your inverter sends through it. So two quite different problems can look the same from the outside:
- The system is not generating. The meter is fine, but there is nothing to count. Look at the inverter’s screen or lights on a bright day. If it shows a fault, or is dark, start with our solar panels not working checks.
- The meter is not counting. The inverter looks healthy and its “generated today” figure keeps rising, but the meter does not move.
A simple test settles it. On a bright day, write down the meter reading and the inverter’s total or “today” figure. Look again after several hours of good light. Only read the displays. Do not open or touch anything.
- Inverter figure has risen, meter has not: the meter is the likely problem.
- Neither has moved: the system is the problem, not the meter.
- Both have moved, but by very different amounts: note both figures and ask an engineer to look.
Give the meter enough time before you decide. Some meters show only whole kilowatt hours. One Emlite model has a flashing light that gives about 1,000 flashes for every kWh generated, so the digits can take a while to tick over. Some meters also cycle through several registers, so wait for the one that shows generation.
Symptoms
Signs the meter itself has failed.
- A blank display that stays blank day and night, while the lights in your home still work.
- Frozen digits. The inverter has generated all day and the meter reading has not changed.
- A reading that falls or jumps wildly. A generation meter should only ever count upwards.
- Physical damage, such as a cracked case, water inside or scorch marks. Do not touch it. Ask an engineer to look straight away. If you see smoke or smell burning, call 999.
Check the make and model on the front label. Common solar generation meters include the Elster A100C and the Emlite ECA2. Take a clear photo of the label and the display, with the serial number in view.
Payments
What it means for your payments.
Your FIT licensee (the company that pays your feed-in tariff) needs a valid reading from the generation meter. Ofgem says estimates cannot be used. The Energy Ombudsman adds that an inverter reading is not a substitute either.
- Payments can pause. The Energy Ombudsman says payments stop from the last accurate meter reading and restart when the new meter is fitted. Nothing is paid for the gap, so do not wait.
- Deemed export is affected too. If you are paid a “deemed” export figure instead of using an export meter, Ofgem says you still need a valid generation reading to receive it.
- Meter checks. Licensees must verify your meter readings at least every two years. EDF says it must suspend payments if a generation meter cannot be verified.
- Smart Export Guarantee (SEG) is separate. SEG pays for what you export, measured by your export meter, not your generation meter. If your export meter is broken, tell your SEG licensee. See our SEG guide.
The FIT is closed to new applicants, so newer systems will not have one.
Tell them
Telling your FIT company.
Tell them as soon as you suspect a fault, in writing, and keep a copy.
- Photograph the fault. Show the blank or frozen display, the serial number and the date. Find your last good reading in your own records or on a FIT statement.
- Do not send estimates. Do not pass off an inverter figure or a guess as a meter reading. Ofgem treats falsified readings as suspected fraud.
- Ask what they need. Your Statement of FIT Terms explains meter ownership and responsibilities. Ask what the licensee needs from you.
- Report the swap once the meter is replaced. Ofgem expects you to tell the licensee when a generation meter is replaced. EDF asks for the exchange date, the old meter’s serial number and final reading, the new meter’s make, model, serial number and start reading, and the reason for the change.
- Keep the evidence. Ofgem expects licensees to ask for invoices and photographs. Photograph the old meter’s final reading and the new meter’s first reading, and keep the installer’s invoice.
Our FIT meter readings guide explains how to photograph and send readings.
Replacement
Getting a new meter fitted.
- It must be an approved meter. Ofgem says FIT meters must be of an approved type. The MCS solar PV standard asks for an MID (Measuring Instruments Directive) approved meter, with the serial number visible on the front so it can be photographed with the make, model and reading.
- Who arranges it. The Energy Ombudsman says the owner must arrange the replacement through the company that installed the system. If that company has gone, see our guide to an installer that has gone bust.
- Who pays. The sources we checked do not set this nationally. Check your Statement of FIT Terms and your installer agreement, and ask your licensee.
- Use a qualified person. The meter sits on the system’s mains wiring. Have an electrician or installer fit it. See solar panel electrician.
- Never tamper. Do not open the meter, break seals, bypass it or rewire it. It is dangerous, and a meter that has been interfered with cannot give a valid reading.
How we help
How we help.
We check whether a system is generating, and repair it if it is not, on systems fitted by any installer across England, Wales and southern Scotland. Our own engineers repair or replace faulty inverters, usually the same week. If the fault turns out to be the meter, we will tell you straight, and we can fit or arrange an approved (MID) generation meter for you. You get a clear written quote before any work starts.
Sources: Ofgem; Energy Ombudsman; MCS; EDF; GOV.UK; Emlite.
Questions
The things people ask before they ring.
Not answered here? Call 0800 156 0191, Monday to Friday, 9:00am–5:00pm.
Can I send my inverter reading instead of the meter reading?
No. The Energy Ombudsman says FIT payments should not be made without accurate readings from the generation meter. Ofgem says estimates cannot be used.
Will I lose FIT payments while the meter is faulty?
Probably for the gap. The Energy Ombudsman says no payments are made between the last accurate reading and the new meter being fitted. Tell your licensee quickly and get the meter replaced without delay.
Does a blank generation meter mean my panels have stopped?
Not necessarily. The meter only counts. Check your inverter on a bright day. If the inverter is generating and the meter is not counting, the meter is the likely fault.
Who pays for a new generation meter?
The sources we checked do not say. Ofgem requires licensee terms to cover meter ownership and responsibilities, so check your Statement of FIT Terms and ask your licensee.
Can I just replace the meter myself?
No. It must be an approved, MID-certified meter, fitted by a qualified person, and your FIT company must be told about the swap.
Ready when you are
Not sure if it’s your meter or your system?
We’ll call you back to talk it through, and you get a clear written quote before any work starts. Mon–Fri 9:00am–5:00pm.