Repairs · Guide
Solar panel electrician or solar engineer: who should you call?
When solar panels stop working, most people’s first thought is to ring an electrician. Sometimes that is exactly right. But a solar system is not quite like the rest of your wiring, and many general electricians prefer not to touch one.
Mon–Fri 9:00am–5:00pm · Clear written quote before any work starts
Talk to us about solar, batteries or repairs.
Call 0800 156 0191, Monday to Friday, 9:00am–5:00pm, or send us a message through our contact page.
MCS certified
NAPIT registered
TrustMark approved
Fully insured
England, Wales & Scotland
What is different
What makes solar different.
This guide explains what is different about solar, which jobs suit a general electrician and which need someone who works on solar every day, the rules on electrical work in your home, and the questions worth asking before you book anyone. If you’re not yet sure what is wrong, start with our guide to solar panels not working.
The panels on your roof produce direct current (DC) whenever light falls on them. You can’t switch them off at the fuse board. The cables from the roof to the inverter can carry a high DC voltage in daylight, even when the inverter itself is off.
Faults on that side of the system, such as isolation faults, failed connectors, optimiser problems or a dead string, need different test equipment and different safety steps from ordinary household wiring. The inverter is a specialist product too, and fault-finding often means reading the manufacturer’s codes and monitoring data. That’s why “solar engineer” and “electrician” aren’t always the same thing.
The rules
The rules on electrical work at home.
In England, electrical work in homes is covered by Part P of the Building Regulations. Approved Document P says: “Reasonable provision shall be made in the design and installation of electrical installations in order to protect persons operating, maintaining or altering the installations from fire or injury.” It lists “photovoltaic panels on roofs” as an example of an installation outside the house that falls within its scope.
Some work has to be notified to building control, including installing a new circuit or replacing a consumer unit (fuse box). Electricians registered with a government-authorised competent person scheme can certify their own notifiable work. GOV.UK says installers can join a competent person scheme “to self-certify certain types of building work” instead of getting building regulations approval. Under Approved Document P, the registered installer gives you a BS 7671 electrical certificate, and you should receive a Building Regulations compliance certificate within 30 days.
These rules are for England. Wales and Scotland have their own building regulations, so the paperwork can differ.
MCS
What about MCS?
MCS certifies installers of small-scale renewables, including solar PV. MCS says using a certified installer helps make sure the technology is “specified, installed and maintained correctly”, and it runs a “find an installer” search on its website.
MCS certification is mainly about new installations, and it is usually what a new system needs to qualify for the Smart Export Guarantee. For a repair on an existing system, the key things are that the engineer is competent with solar PV, registered for electrical work where it matters, and insured. If your original installer has gone out of business, MCS says its helpdesk can still help with certificate questions. See our guides to installer gone bust and lost MCS certificates.
Which jobs
Which jobs suit which person.
As a rough guide:
- A general electrician is the right call for faults in your home’s wiring that have nothing to do with the solar system, such as a socket circuit tripping or a new circuit.
- A solar engineer is the right call for anything on the DC side, the inverter, optimisers, isolators, monitoring, generation meters, or a breaker labelled solar or PV that keeps tripping.
- Either may be suitable for a fault on the AC cable between the inverter and the fuse board, as long as they are confident with solar systems.
- Anything on the roof needs safe access, which usually means scaffolding. It isn’t a job for a ladder.
If you aren’t sure which side the fault is on, a solar engineer can usually tell you quickly, because a solar health check covers the whole system from the panels to the meter.
Specialist faults
Faults that usually need a solar specialist.
Some problems almost always come back to the solar side of the system. If any of these sound familiar, it’s worth calling someone who works on solar every day:
- an inverter showing an isolation, earth or insulation fault (see isolation faults);
- a breaker labelled solar or PV that trips again and again;
- optimisers reporting faults or dropping out (see solar optimisers);
- the monitoring app has stopped updating (see monitoring offline);
- the inverter is noisy, hot or showing red lights;
- panels damaged by a storm (see storm damage);
- pigeons nesting under the panels and chewing cables (see bird proofing).
Many of these can be narrowed down before anyone climbs a ladder, by reading the inverter’s fault history and monitoring data. That is where solar experience saves time.
Questions to ask
Questions to ask before you book.
- Do you work on solar PV regularly, and on systems you didn’t install?
- Have you worked on my inverter brand before?
- Are you registered with a competent person scheme for electrical work?
- Are you fully insured?
- Will I get a written report of what you found?
- Will I get a written quote before any repair work starts?
- If a part needs replacing, will that affect the manufacturer’s cover?
A good engineer won’t mind any of these questions.
Before a visit
What you can do before anyone visits.
You can save time, and often money, by gathering a few facts first. Please stay on the ground and away from the roof and the DC cabling. Checks from the fuse board, the meter cupboard or the loft are fine.
- Note the inverter’s lights and any code on its screen (see solar inverter error codes).
- Take a generation meter reading now and another in a week.
- Check the monitoring app for when output dropped.
- Note whether a breaker labelled solar or PV has tripped, but don’t keep resetting it (see tripping RCD).
- Find your paperwork: the MCS certificate, the handover pack and any inverter manual.
How we help
How we help.
We install our own systems and repair everyone else’s, so we know exactly how they fail. Repair is our core business, so there’s no pressure to rip out and replace.
Our own in-house engineers, not agents, work on systems fitted by any installer, on any brand, across England, Wales and southern Scotland. We are NAPIT registered, TrustMark approved and fully insured, and MCS certified for solar PV. Through NAPIT we can certify notifiable electrical work ourselves. Every repair visit leaves you with a written report, we offer same-week inverter repair or replacement, and we arrange scaffolding ourselves when roof work is needed. We also take on ordinary domestic electrical work that isn’t connected to your solar. You get a clear written quote before any work starts. Find out more about solar panel repair.
Sources: Department for Communities and Local Government, Approved Document P: Electrical safety – dwellings (2013 edition, England); GOV.UK, Competent person scheme (updated September 2026); MCS, Consumer FAQs.
Questions
The things people ask before they ring.
Not answered here? Call 0800 156 0191, Monday to Friday, 9:00am–5:00pm.
Can any electrician work on solar panels?
Any qualified electrician can work on household wiring, but many prefer not to work on the DC side or the inverter. For those, choose someone who works on solar PV regularly.
Do I need an MCS certified installer to repair my solar panels?
MCS certification mainly covers new installations. For a repair, look for an engineer who is experienced with solar PV, registered for electrical work and insured.
What does a solar engineer do?
They find and fix faults across the whole system: panels, cabling, isolators, optimisers, the inverter, monitoring and the generation meter.
Will a repair affect my manufacturer’s cover?
Proper servicing doesn’t void a manufacturer’s cover, but check the terms before any part is replaced and keep the paperwork.
Is it safe to look at my solar panels myself?
Yes, from the ground. Don’t climb onto the roof, touch the panels or go near the DC cabling.
Ready when you are
Not sure who to call about your solar?
We’ll call you back to talk it through, and you get a clear written quote before any work starts. Mon–Fri 9:00am–5:00pm.