Solar inverter error codes: what they mean and what to do
A red light, a beep or a code on the inverter screen is often the first sign that something has changed in a solar PV system. Most error codes fall into a handful of families, and the family tells you a lot about where the problem is. Some faults clear on their own once conditions return to normal. Others need an engineer. For what the lights and alarms mean, see inverter lights and beeping.
Mon–Fri 9:00am–5:00pm · Clear written quote before any work starts
Talk to us about solar, batteries or repairs.
Call 0800 156 0191, Monday to Friday, 9:00am–5:00pm, or send us a message through our contact page.
MCS certified
NAPIT registered
TrustMark approved
Fully insured
England, Wales & Scotland
Why it happens
Why your inverter shows an error code.
This guide explains the main types of inverter error code, uses real examples from manufacturers’ own manuals, and sets out the checks you can safely make from the ground and the fuse board.
The inverter is the part of the system that turns the direct current (DC) from the panels into the alternating current (AC) your home uses. It is also the system’s safety monitor. It constantly measures the grid supply, the panels and its own internal parts, and it stops exporting power when something is outside its limits.
When it stops, it records why. That record is the error code. Depending on the make and age of the inverter, you may see it on the inverter’s screen, as a coloured light, in the monitoring app or website, or as an email alert. SolarEdge’s troubleshooting guide, for example, says its codes are made of “four hexadecimal characters, separated by the character x in the middle” (such as 2×19), and that they are “also displayed over SolarEdge platform”.
Code families
The main families of error code.
Codes vary by brand, but nearly all of them belong to one of these groups:
- Grid faults: the mains voltage or frequency is outside the limits the inverter must work within.
- No grid or “waiting for grid”: the inverter can’t see the mains supply at all.
- Isolation or insulation faults: some current is leaking from the DC side of the system to earth.
- Residual current or leakage faults: a closely related group, picked up by the inverter’s own current monitoring.
- Arc faults: the inverter has detected the signature of an electrical arc on the DC side.
- Internal and communication faults: a problem inside the inverter or between it and its monitoring.
Grid faults
Grid faults: often outside your home.
All small inverters in Great Britain have to meet the Energy Networks Association’s Engineering Recommendation G98. It sets the limits at which an inverter must disconnect. In Issue 2 (10 March 2025), the first over-voltage stage is “+14% = 262.2 V” for 1.0 second, and under-voltage is “-20% = 184 V” for 2.5 seconds, measured against 230 V.
G98 also says the inverter may only reconnect once the voltage and frequency have been within limits “for a minimum of 20 s”. So a grid fault that clears on its own, with the system back up a minute later, is the system working as designed.
Manufacturers’ codes reflect this. SolarEdge lists codes such as 2x1F (“Grid voltage is above the country limit”) and 2×20 (“Grid voltage is below the country limit”). SMA’s manual for its single-phase Sunny Boy range lists event 302, where “The inverter has reduced its power due to a too-high grid voltage to ensure grid stability.” Both manufacturers suggest contacting the grid operator if it keeps happening.
If grid faults keep appearing on sunny afternoons, high local voltage is a possible cause, but the fault may also be in the AC connection to the inverter. An engineer can measure it and help you raise it with your network operator.
Isolation faults
Isolation and leakage faults: leave these to an engineer.
An isolation fault means the DC side of the system is not properly insulated from earth. SolarEdge describes codes 2×19 and 8×58 as “PV solar array is not properly isolated from ground earth” and says “Only a certified PV installer must fix the faulty string.” SMA’s event 3501, “Insulation failure > Check generator”, has the same cause: “The inverter has detected a ground fault in the PV array.” SMA’s events 3601 and 3701 cover leakage and residual current from the same kind of problem.
Water in a connector, a damaged cable or a failing panel are common causes. These faults often appear on damp mornings and clear later, which makes them easy to ignore. Please don’t. The panels are live in daylight, and the DC cabling can carry a dangerous voltage even when the inverter is off. Our guide to isolation faults explains more, and if a breaker is tripping, see why a solar RCD keeps tripping.
Inverter faults
Codes that point to the inverter itself.
Some codes mean the fault is inside the inverter. SMA says that for its event range 6001 to 6438, “The cause must be determined by the Service.” SolarEdge’s “Internal communication error” codes (8×10 and 33×10) say “Contact SolarEdge Support.”
These codes are more common as inverters get older. Many domestic inverters are replaced at some point in a system’s life. The Energy Saving Trust says you are likely to need to replace an inverter “after around 12 years”. Our guide to how long solar inverters last covers the signs.
Safe checks
What you can safely check.
These checks need no tools and keep you well away from the panels and the DC cabling:
- Write down the exact code and the time, or take a photo of the screen or app. The exact wording matters.
- Check your monitoring to see when generation stopped and whether the fault keeps coming back.
- Ask a neighbour whether there was a power cut. A grid problem can stop every inverter in the street.
- Look at the fuse board. If the breaker labelled solar or PV is off, you can switch it back on once. SMA’s event 801 suggests checking the AC circuit breaker. If it trips again, leave it off and call an engineer.
- Check the generation meter is still counting on a sunny day.
Please don’t open the inverter, don’t touch the DC isolator or any cabling, and never go on the roof. Don’t keep resetting a breaker that trips, and don’t replace a blown fuse yourself.
By brand
Brand-by-brand code lists.
If you know your make, our brand pages list common codes from the manufacturers’ manuals: SolarEdge, Fronius, SMA, Growatt, Solis, SolaX, Power-One and ABB Aurora and Sofar. If your inverter is a hybrid that also runs a battery, see our hybrid inverters guide.
How we help
How we help.
We install our own systems and repair everyone else’s, so we know exactly how they fail. Our own engineers repair systems fitted by any installer, on any brand, across England, Wales and southern Scotland. We offer same-week inverter repair or replacement, and we can set up monitoring before we leave so you can see future faults straight away.
Repair is our core business, so there’s no pressure to rip out and replace. You get a clear written quote before any work starts. Tell us the code you are seeing when you call and we will tell you what it is likely to mean. You can also try our fault finder or read more about inverter repair.
Sources: SolarEdge, Inverters Error Codes and Troubleshooting; SMA, Sunny Boy SBxx-1VL-40 manual; Energy Networks Association, Engineering Recommendation G98 Issue 2 (10 March 2025); Energy Saving Trust, Solar panels.
Questions
The things people ask before they ring.
Not answered here? Call 0800 156 0191, Monday to Friday, 9:00am–5:00pm.
Why is my solar inverter beeping?
Many inverters beep or sound an alarm when they record a fault. Note the code on the screen or in the app and check the fuse board. If it keeps sounding, call an engineer rather than opening the unit.
Will the error code clear by itself?
Grid faults often do. Under G98 the inverter can reconnect once voltage and frequency have been within limits for at least 20 seconds. Isolation, leakage, arc and internal faults usually need investigating even if they clear.
Is it safe to switch the inverter off and on again?
Switching the solar breaker at the fuse board off and back on once is fine. Don’t touch the DC isolator or any cabling, and leave the breaker off if it trips again.
Does a red light always mean a fault?
On most makes, a red light or red symbol means the inverter has stopped because of a fault. Check what your make’s manual says, and look at the monitoring to confirm generation has stopped.
Can you repair an inverter another company fitted?
Yes. We repair systems fitted by any installer, on any brand.