Solar inverter isolation fault: what it means and how it’s fixed

An isolation fault, also called an insulation or earth fault, means your inverter has found electricity leaking from the panel wiring to earth. It’s one of the most common solar faults. The inverter stops generating to keep the system safe, so you lose output until it’s found and fixed.

Mon–Fri 9:00am–5:00pm · Clear written quote before any work starts

Start here

Talk to us about solar, batteries or repairs.

Call 0800 156 0191, Monday to Friday, 9:00am–5:00pm, or send us a message through our contact page.

MCS certified

NAPIT registered

TrustMark approved

Fully insured

England, Wales & southern Scotland

Safety

Safety first.

Here’s what causes it, why it often comes and goes, the codes each inverter brand uses, and how an engineer tracks it down. For other inverter codes, see our inverter error codes guide.

  • Don’t touch the panels, the cables from the roof or the DC isolator. The panel side stays live in daylight, and an isolation fault means some of that wiring isn’t properly insulated.
  • Don’t keep resetting the inverter. The fault is a warning, and the inverter is doing its job by stopping.
  • Burning smell, smoke or scorch marks: keep clear and call an engineer. If there’s any sign of fire, call 999. See can solar panels catch fire?

The test

What the inverter is checking.

Before it connects to the grid each morning, and while it runs, the inverter measures the insulation resistance between the panel wiring and earth. Healthy wiring has a very high resistance, so almost no current can leak. If the reading drops below the inverter’s limit (often around 1 MΩ, depending on the make and settings), it shows a fault and won’t connect.

So the fault isn’t usually in the inverter itself. The inverter is reporting a problem somewhere on the panel side.

Causes

Common causes.

  • Water in a connector. The plug-and-socket connectors between panels and on the cables to the roof can let water in if they’re damaged, mismatched or badly fitted.
  • Damaged cable. Cable rubbed through on a roof edge or tile, crushed under a fixing, or chewed by birds or rodents.
  • A faulty panel. Cracked glass, a damaged backsheet or a failing junction box on the back of a panel.
  • Optimisers. On SolarEdge and similar systems, a faulty optimiser or its connectors can cause it. See solar panel optimisers.
  • A wet DC isolator. Water inside the isolator enclosure. See solar panel isolator switches.
  • Storm or roof work. Panels lifted in a storm, or cables disturbed by roofers or satellite fitters. See storm-damaged solar panels.

Damp mornings

Why it comes and goes.

Many isolation faults show up on damp or dewy mornings and clear by lunchtime. Moisture makes a small weakness leak more. As the system dries, the reading rises and the inverter connects again. If there’s no fault code and the inverter just stays in standby in daylight, see inverter stuck in night mode.

That doesn’t mean it’s fixed. The weak spot is still there, it usually gets worse, and every morning it costs you generation. A fault that clears on its own still needs testing. If it also trips your RCD or fuse box, see solar tripping the RCD. See solar PV electrical testing for what the tests involve.

Codes

The codes by inverter brand.

Finding it

How an engineer finds it.

  1. Check the monitoring and fault log to see when it happens and how often.
  2. Make the system safe and isolate the panel side.
  3. Test each string with an insulation resistance tester to find which part of the array has the fault.
  4. Narrow it down to a cable run, a connector, an optimiser or a panel, and check the isolators and the inverter.
  5. Repair or replace the faulty part, then retest and check the system is generating.

A fault on the roof may need safe access, such as a roof ladder or scaffold, and finding it can take time if it only appears in damp weather.

How we help

How we help.

We find and fix isolation and earth faults on any make of inverter, on systems fitted by any installer, across England, Wales and southern Scotland. Our engineers test the array string by string, put right what’s wrong, and give you a clear written quote before any work starts.

Sources: Inverter manuals from SolarEdge, SMA, Growatt, SolaX, Sofar and Power-One/ABB (see our brand pages); Solis, PV Isolation Protection; Secondsol, Insulation fault in PV systems.

Questions

The things people ask before they ring.

Not answered here? Call 0800 156 0191, Monday to Friday, 9:00am–5:00pm.

What does isolation fault mean on a solar inverter?

The inverter has measured too low a resistance between the panel wiring and earth, so some current could leak to earth. It stops generating to stay safe. The fault is usually on the panel side, not in the inverter.

Why does my isolation fault only happen in the morning?

Dew and damp make a small weakness, such as water in a connector, leak more. As the panels and cables dry out, the fault clears and the inverter reconnects. The weak spot is still there and needs testing.

Is an isolation fault dangerous?

It means some of the panel wiring isn’t properly insulated, so it shouldn’t be ignored. Don’t touch the panels, cables or DC isolator, and don’t keep resetting the inverter. If you smell burning or see scorch marks, keep clear and call an engineer.

Can I fix an isolation fault myself?

No. Finding it means isolating and testing the panel side, which stays live in daylight. It needs an engineer with an insulation tester.

Will a new inverter fix an isolation fault?

Usually not, because the fault is normally in the panels, cables or connectors. A new inverter would show the same fault. Occasionally the inverter itself is the cause, which testing will show.

Ready when you are

Isolation or earth fault on your inverter?

We’ll call you back to talk it through, and you get a clear written quote before any work starts. Mon–Fri 9:00am–5:00pm.