Solar inverter stuck in night mode, standby or waiting during the day?
If your inverter says “night mode”, “standby” or “waiting” in the middle of a bright day, it is telling you it can’t see enough power coming from the panels to start. At dawn, at dusk and on very dark winter days, that is normal. At midday on a clear day, it usually means something has gone wrong on the panel side.
Mon–Fri 9:00am–5:00pm · Clear written quote before any work starts
Talk to us about solar, batteries or repairs.
Call 0800 156 0191, Monday to Friday, 9:00am–5:00pm, or send us a message through our contact page.
MCS certified
NAPIT registered
TrustMark approved
Fully insured
England, Wales & Scotland
Meaning
What the message means.
Below we explain what each message means, how to tell normal from faulty, and what you can safely check yourself.
An inverter wakes up when the panels give it enough voltage to start. Until then, it sits and waits. Each make has its own word for this, but they all describe the same thing: the DC side (the cables from your panels) isn’t delivering enough to get going.
In the early morning and late afternoon the light is weak, so the inverter starts late and stops early. Heavy cloud, deep shade and snow lying on the panels can do the same.
It becomes a problem when:
- It lasts through the middle of a bright day. If the screen still says night mode or waiting at midday under a clear sky, the panels aren’t reaching the inverter.
- It has gone on for more than a day. One dull spell is normal. Several bright days in a row with no generation is not. (This is general trade experience, not a manufacturer rule.)
- It started after something changed. A storm, roof work, scaffolding, panel cleaning or bird proofing can all disturb the DC side.
Faults
When it points to a fault.
If the panels are in daylight but the inverter still sees almost no voltage, the problem sits somewhere between the panels and the inverter, or in the inverter’s own DC input. Common causes are:
- A DC isolator that has been switched off. The DC isolator is the switch that cuts the panel supply to the inverter. If it is off, the inverter sees nothing. Read more about isolator switches. Please don’t operate it yourself.
- A broken string. Panels are wired in a chain called a string. One failed connector or damaged cable can break the whole chain.
- An isolation fault. This is a leak of current from the DC wiring to earth, often from damaged cable insulation, a bad connector or moisture. Some inverters refuse to start while it is present. See our guide to isolation faults.
- A failed optimiser. Where your system has optimisers (small units behind each panel), a faulty one can stop the string from coming up. See optimisers.
- A faulty DC input or MPPT stage. The MPPT is the part of the inverter that handles the incoming panel power. If it has failed, the inverter can’t start even with healthy panels.
An engineer has to test the DC side to tell these apart. The screen alone can’t.
By make
What the makers say.
We only list what we have been able to check in manufacturer documents. If your make isn’t here, the same principle applies.
- SolarEdge. SolarEdge describes Night Mode as a status meaning the input voltage from the panels is too low. For this status, its error-code guide says to test the DC side and contact support. SolarEdge optimisers also hold their output at about 1 V each as a safety measure until the inverter is running. The inverter’s status screen shows a P_OK count of optimisers reporting in. If the numbers don’t match, one or more optimisers may have a problem. More on SolarEdge repairs.
- SMA. SMA’s manuals use “Waiting for DC start conditions”. The generator voltage is too low, or the feed-in conditions aren’t met yet. SMA’s advice is to wait for stronger light and make sure the panels aren’t covered by snow or shaded. On Sunny Boy models, a flashing green light means “waiting for feed-in conditions”. SMA also says that if the inverter finds the DC insulation resistance is too low, it won’t connect to the grid.
- Growatt. Growatt’s MIN TL-X manual shows a green light that is on for half a second, then off for two seconds, as “Standby”. It says the inverter starts by itself once the input voltage rises above 70 V.
- Solis. Solis lists “Waiting” as the inverter checking whether the DC input voltage has reached the minimum starting voltage.
- Fronius. Fronius says that status messages 306 “Power low” and 307 “DC low” appear routinely in the early morning and evening and are not a fault. Fronius also has a manual “Standby” setting that stops feeding the grid. The display then alternates between STANDBY and ENTER, and it only ends when someone presses the Enter key. If your Fronius shows that, ask whoever has been near the inverter, then tell us.
Check first
Safe checks you can do.
You don’t need to open anything or go near the panels. Stay off the roof and away from cables. The panels make electricity whenever it is light, even when the inverter has stopped.
- Read the inverter screen. Write down the exact words, any code, and the time of day. Take a photo if you can.
- Look at the lights. Note the colour and whether they are steady or flashing.
- Check the fuse board. Look at your consumer unit for a switch labelled solar, PV or inverter that has dropped. If one has tripped, tell us before you reset it again, because repeated tripping can point to an earth or isolation fault.
- Look at the generation meter. Note the reading on a bright morning and again in the afternoon. If it hasn’t moved, you aren’t generating.
- Check the app. Look at the daily graph. A flat line on a bright day, or a date when generation stopped, helps us a great deal. If the app has also gone offline, our monitoring offline guide may help.
- Think about what changed. Storm, roof work, cleaning, new battery, a visit from another trade.
Please don’t switch the inverter or any isolator off and on to “reset” it. Don’t open the inverter or touch DC cables either. The panel side stays live in daylight.
How we help
How we help.
Our own engineers repair solar systems fitted by any installer, across England, Wales and southern Scotland. We find out why your inverter isn’t waking up, whether that is an isolator, a string, a connector, an optimiser or the inverter itself, and tell you plainly what we found. You get a clear written quote before any work starts. For more on inverter problems, see inverter repair.
Sources: SolarEdge; SMA; Growatt; Solis; Fronius.
Questions
The things people ask before they ring.
Not answered here? Call 0800 156 0191, Monday to Friday, 9:00am–5:00pm.
Why does my inverter say night mode when it is daytime?
It can’t see enough voltage from the panels to start. In the early morning, late afternoon or on a very dark day, that is normal. At midday on a bright day, it points to a fault on the DC side, such as a switched-off isolator, a broken string or a failed part.
Is “standby” always a fault?
No. Many inverters show standby or waiting while they wait for enough light. Fronius also has a manual standby setting that someone can switch on. It is a fault if it persists through bright daylight or the inverter isn’t generating.
Can I fix it by turning the inverter off and on again?
No. Please don’t switch isolators or the inverter off and on. The panel side is live in daylight, and a fault on the DC side won’t clear by resetting. Write down what the screen says and call us.
My app says the inverter is online. Can it still be asleep?
Yes. Online only means the inverter can talk to the internet. It says nothing about whether the panels are feeding it.
Will I lose money while it’s stuck?
You aren’t paid for electricity your system doesn’t generate, and you pay for more from the grid. Note the date it started and your meter reading. Our meter readings guide explains how readings and payments fit together.