Solar panels are quiet. There is nothing to hear and nothing moves, so a fault can go unnoticed for weeks. Many people only find out something is wrong when a Feed-in Tariff payment or an electricity bill looks odd.
Mon–Fri 9:00am–5:00pm · Clear written quote before any work starts
Talk to us about solar, batteries or repairs.
Call 0800 156 0191, Monday to Friday, 9:00am–5:00pm, or send us a message through our contact page.
MCS certified
NAPIT registered
TrustMark approved
Fully insured
England, Wales & Scotland
Check 1
Check 1: read the generation meter.
The good news is that you can check a system in a few minutes without going near the roof. This guide sets out five safe checks, explains what level of output is normal, and lists the signs that mean it is time to call an engineer. If you already know your system has stopped, start with our guide to solar panels not working.
Every MCS-certified system should have a way of recording what it produces. MCS’s installation standard (MIS 3002: 2025) says “A means of recording and displaying the total AC generation of the system shall be installed.” In most homes this is a separate generation meter near the inverter or the fuse board, often in the loft, garage or under the stairs.
On a bright day, the meter should be counting up. On older meters a light flashes or a disc turns; digital ones show a rising total. Write the reading down, then read it again at the same time a week later. The difference is your weekly output.
If you have a smart meter, your electricity bill or energy app may also show how much you exported, which is another clue. If the generation reading hasn’t moved on a sunny day, the system is not generating, or the meter itself has a problem. Our guide to Feed-in Tariff meter readings explains how to read the common types.
Check 2
Check 2: look at the inverter.
The inverter turns the panels’ power into electricity your home can use. Most have a screen or a set of lights. A green light or a figure showing power being produced is a good sign. A red light, a warning symbol or a code usually means it has stopped. Our guide to solar inverter error codes explains what the common codes mean.
It is normal for the screen to go blank at night and to show little on dull days. Look at the inverter around midday on a bright day for the most useful picture.
Check 3
Check 3: open the monitoring app.
Many systems send data to an app or website. The Energy Saving Trust notes that “Some inverters have online monitoring functions and can warn you by email if the system fails.” For newer installations, MCS’s 2025 standard says a means of notifying the customer “within 48 hours of the system ceasing to operate” should be provided.
Look at the daily graph. On a clear day you would expect a smooth curve that rises in the morning and falls in the evening. Flat days, sudden drops to zero or a curve that is cut off at midday are worth noting. If the app has stopped updating, the problem may just be the Wi-Fi link. See our guide to solar monitoring that has gone offline.
Check 4
Check 4: compare with what to expect.
Output changes a great deal through the year, so compare like with like. The best guide is the MCS performance estimate you were given when the system was installed, which is based on your roof and location. Compare this year’s total for a month with the same month last year.
A simple log helps. Note the meter reading on the first of each month in a notebook or on your phone. After a year you will have your own pattern, which is far more useful than any national average, and a sudden gap will stand out straight away.
To give a sense of scale, MCS publishes regional figures that installers use in its estimate method. For a south-facing roof at a 35° pitch, the figure is 984 kWh per kWp a year for the London zone and 865 for the Manchester zone. Real systems produce less than this once shading and other losses are taken into account. Our arithmetic: a 4 kWp south-facing system in the Manchester zone has a starting figure of about 3,460 kWh a year before those losses.
PV generation is an estimate using the MCS method and varies with the weather. A dull summer can be well down on a bright one. Read more in how much electricity do solar panels generate.
Check 5
Check 5: look at the panels from the ground.
From the garden or the street, look for anything obvious: a cracked or discoloured panel, a slipped panel, heavy bird mess, moss or leaves, or new shade from a growing tree. The Energy Saving Trust’s main maintenance tip is to “keep nearby trees well-trimmed to minimise shading where possible.” Pigeons nesting under the panels can also damage cables over time. See our bird proofing page.
Use binoculars if it helps, but please stay on the ground. Never climb onto the roof, and never touch the panels or the DC cabling. Panels are live in daylight.
Safety
What not to do.
Some online guides suggest testing panels with a multimeter. We don’t recommend it for homeowners. The DC side of a system can carry a dangerous voltage even when the inverter is off. Please also:
- don’t open the inverter or any isolator box;
- don’t keep resetting a breaker that trips at the fuse board;
- don’t replace a blown fuse yourself;
- don’t try to clean panels from a ladder (see how to clean solar panels).
Call an engineer
Signs it’s time to call an engineer.
- The generation meter hasn’t moved on a sunny day.
- The inverter shows a red light, a fault code or nothing at all in daylight.
- Output is well below the same month last year, with similar weather.
- A breaker labelled solar or PV keeps tripping (see tripping RCD).
- You can see damage, scorch marks or loose cables.
- The inverter is making new noises or getting very hot.
Lower output in winter is normal. See solar panels in winter for what to expect.
How we help
How we help.
We install our own systems and repair everyone else’s, so we know exactly how they fail. Our own engineers look after systems fitted by any installer, on any brand, across England, Wales and southern Scotland.
Our standard health check comes with a written report on the condition of your system. If we find a fault, you get a clear written quote before any work starts, and repair is our core business, so there’s no pressure to rip out and replace. We offer same-week inverter repair or replacement and can set up monitoring before we leave, so you can keep an eye on things yourself. Find out more about solar panel servicing.
Sources: MCS, Solar PV: Installation Standard, MIS 3002: 2025; MCS Irradiance Datasets (guidance v2.0); Energy Saving Trust, Solar panels.
Questions
The things people ask before they ring.
Not answered here? Call 0800 156 0191, Monday to Friday, 9:00am–5:00pm.
How do I know if my solar panels are working?
Check that the generation meter is counting on a bright day, the inverter shows no fault, and the monitoring graph looks normal. Then compare your monthly output with the same month last year.
Can I test my solar panels myself?
You can make the checks in this guide from the ground and the meter cupboard. Testing the panels or cabling electrically should be left to an engineer.
Why are my solar panels producing less than last year?
Weather is the most common reason. Other causes include new shade, dirt, a failing panel or an inverter fault. If the drop is large, have the system checked.
How often should I check my solar panels?
A quick look at the meter or app once a week, and a monthly reading, is enough to spot most problems early.
Do solar panels need servicing?
The panels need little care, but the inverter and connections wear over time. See our guide to solar panel maintenance.