Repairs · Guide
Solar iBoost not working? Common faults and what they mean
A solar iBoost is a diverter. Instead of sending spare solar electricity out to the grid, it sends it to your immersion heater so you get hot water from your own panels. When it works, you hardly notice it. When it stops, the first sign is often a cold tank or a higher gas bill.
Mon–Fri 9:00am–5:00pm · Clear written quote before any work starts
Talk to us about solar, batteries or repairs.
Call 0800 156 0191, Monday to Friday, 9:00am–5:00pm, or send us a message through our contact page.
MCS certified
NAPIT registered
TrustMark approved
Fully insured
England, Wales & Scotland
How it works
How a Solar iBoost works.
The good news is that many iBoost problems are simple: a flat battery in the sender, a clamp that has been moved, or a thermostat doing its job. This guide explains the on-screen messages Marlec, the maker, lists for the Solar iBoost+, what you can safely check, and when to call an electrician or a solar engineer. If you are still deciding whether a diverter is right for you, see our guide to solar diverters.
The system has three parts. A clamp sits around the main electricity cable, usually at the main meter (not the solar generation meter) or the fuse board. A small battery-powered sender next to it reads the clamp. The main unit, wired to the immersion heater, listens to the sender by radio.
When the sender sees electricity flowing out to the grid, the main unit diverts it into the immersion. Marlec says the unit only works when excess generation or export is above 100W (200W on the original model). On a dull winter day there may be no spare power at all, so “nothing happening” can be perfectly normal.
Normal messages
“Heating by Solar” and “Water Heating Off”.
Heating by Solar is the normal working message. Marlec says the light flashes blue and the screen shows the power being diverted. To test it, switch on a kettle: diversion should stop or drop, because the kettle is now using the spare power.
Water Heating Off means no spare power is being detected and the unit is on standby. That is expected at night and on cloudy days. If your panels are clearly producing on a bright day and the screen still says Water Heating Off, Marlec’s first suggestion is to check that the clamp is fitted correctly. It may have been removed or moved, for example during a meter change. A smart meter installation is a common time for this to happen.
If the unit shows Heating by Solar at night, the clamp may be on the wrong way round or in the wrong place, or a home battery may be exporting small amounts of power. Marlec says the iBoost and battery cut-in settings can be adjusted so they don’t compete, but only on models from May 2019.
Tank hot
“Water Tank Hot”.
This message means there is spare power, but the immersion’s own thermostat has reached its set temperature and switched off. In other words, the tank is full of hot water and there is nowhere else for the energy to go.
If your water isn’t actually hot, Marlec says the thermostat may be set too low or may be faulty. It advises that “A qualified electrician should inspect the installation.” Please don’t take the cover off the immersion heater yourself: it is mains wiring.
Sender
“Sender Battery Low” and “Lost Signal to Sender”.
These are the most common messages, and often the easiest to fix.
- Sender Battery Low: replace the two AA batteries in the sender. Marlec says not to use rechargeable batteries and to mount the sender upright rather than flat.
- Lost Signal to Sender: the main unit isn’t hearing the sender. Solar heating stops, although Marlec says manual and timed boost still work. Causes it lists are flat sender batteries, the unit being too far from or too close to the sender, or the sender’s pairing button being pressed by accident. The fix is usually new batteries, then re-pairing the sender and main unit using Marlec’s pairing guide.
The sender sits beside the meter or fuse board. Changing its batteries doesn’t involve opening any electrical equipment, but if the sender is inside a locked or sealed meter cupboard, leave it to an electrician.
Overload and cooling
“Maximum Power”, “Unit Cooling” and a blank screen.
Maximum Power means the unit has detected an overload on the heating circuit and switched its output off. Marlec says to check that the immersion load and supply voltage are within its specification, and that “The warning can be reset by power cycling the Solar iBoost+ unit once any issue has been eliminated.” Checking the immersion element is a job for an electrician.
Unit Cooling means the iBoost is protecting itself from heat. Marlec says “There should be 100mm clearance all around” the unit. Move stored boxes or towels away from it.
A blank screen usually means there is no power to the unit. Look at the fuse board for a tripped breaker or switched-off spur, but don’t keep resetting one that trips again. If there is power and the screen is still blank, Marlec says the unit has to be returned for investigation, and an electrician may be needed to remove it.
Safe checks
What you can safely check.
- Read the message on the screen and note when it appears.
- Switch a kettle on during Heating by Solar to see if diversion drops.
- Replace the sender’s AA batteries if it says Sender Battery Low.
- Check the immersion switch and timer are set as you expect.
- Make sure the main unit has clear space around it.
- Check your solar system itself is producing. If the panels have stopped, the iBoost has nothing to divert. Our guide on how to check your solar panels are working can help.
Please don’t open the main unit, the immersion heater or the meter cupboard, and never go onto the roof.
Get help
When to get help.
- The clamp needs moving or refitting after a meter change.
- Water Tank Hot shows but the water is cold.
- Maximum Power keeps coming back.
- The screen is blank even though the circuit has power.
- Heating happens at night, or the iBoost and a home battery seem to be fighting.
- Your solar output has dropped, so there is little left to divert.
How we help
How we help.
We install our own systems and repair everyone else’s, so we know exactly how they fail. Our own engineers look after systems fitted by any installer, on any brand, across England, Wales and southern Scotland.
We repair, refit and re-pair solar iBoost and other diverter units, including moving the clamp after a meter change, and we can fit or replace immersion heaters and thermostats. We can also adjust the cut-in settings so a diverter and a home battery don’t compete for spare power. A diverter fault is often really a solar fault, so we look at the whole system: the panels, the inverter and how the diverter is set up. Repair is our core business, so there’s no pressure to rip out and replace, and you get a clear written quote before any work starts. Find out more about solar panel repair.
Sources: Marlec Engineering, Troubleshoot my Solar iBoost and on-screen messages guide (last modified February 2025).
Questions
The things people ask before they ring.
Not answered here? Call 0800 156 0191, Monday to Friday, 9:00am–5:00pm.
Why is my solar iBoost not heating water?
Usually there isn’t enough spare solar power, the tank is already hot, or the sender has lost contact. Check the screen message first.
How do I fix Lost Signal to Sender on my iBoost?
Fit new AA batteries in the sender (not rechargeables), then re-pair it with the main unit using Marlec’s pairing guide.
Does a solar iBoost work in winter?
Only when your panels produce more than your home is using. On short, dull days there may be little or nothing to divert.
Can I use a solar iBoost with a battery?
Yes, but the two can compete for spare power. Marlec says newer models let the cut-in thresholds be adjusted so they work together, and we can set that up.
Who repairs a solar iBoost?
We do. Our engineers can repair, refit and re-pair the unit, and look at the immersion and the solar system at the same visit.
Ready when you are
iBoost or diverter not heating your water?
We’ll call you back to talk it through, and you get a clear written quote before any work starts. Mon–Fri 9:00am–5:00pm.